Effect of ion mass and charge state on transport of vacuum ARC plasmas through a biased magnetic filter
Skip to main content
eScholarship
Open Access Publications from the University of California

Effect of ion mass and charge state on transport of vacuum ARC plasmas through a biased magnetic filter

Abstract

The effect of ion mass and charge state on plasma transport through a 90o-curved magnetic filter is experimentally investigated using a pulsed cathodic arc source. Graphite, copper, and tungsten were selected as test materials. The filter was a bent copper coil biased via the voltage drop across a low-ohm, "self-bias" resistor. Ion transport is accomplished via a guiding electric field, whose potential forms a "trough" shaped by the magnetic guiding field of the filter coil. Evaluation was done by measuring the filtered ion current and determination of the particle system coefficient, which can be defined as the ratio of filter ion current, divided by the mean ion charge state, to the arc current. It was found that the ion current and particle system coefficient decreased as the mass-to-charge ratio of ions increased. This result can be qualitatively interpreted by a very simply model of ion transport that is based on compensation of the centrifugal force by the electric force associated with the guiding potential trough.

Main Content
For improved accessibility of PDF content, download the file to your device.
Current View