Skip to main content
eScholarship
Open Access Publications from the University of California

UC Berkeley

UC Berkeley Electronic Theses and Dissertations bannerUC Berkeley

Seismic Earth Pressures on Retaining Structures and Basement Walls in Cohesionless Soils

Abstract

Observations of the performance of basement walls and retaining structures in recent earthquakes show that failures of basement or deep excavation walls in earthquakes are rare even if the structures were not designed for the actual magnitude of the earthquake loading. Failures of retaining structures are most commonly confined to waterfront structures retaining saturated backfill with liquefaction being the critical factor in the failures. Failures of other types of retaining structures are relatively rare and usually involve a more complex set of conditions, such as sloping ground either above or below the retaining structure, or both. While some failures have been observed, there is no evidence of a systemic problem with traditional static retaining wall design even under quite severe loading conditions. No significant damage or failures of retaining structures occurred in the recent earthquakes such as Wenchuan earthquake in China (200) and, or subduction zone generated earthquakes in Chile (2010) and Japan (2011). Therefore, this experimental and analytical study was undertaken to develop a better understanding of the distribution and magnitude of seismic earth pressures on cantilever retaining structures.

The experimental component of the study consists of two sets of dynamic centrifuge model experiments. In the first experiment two model structures representing basement type setting were used, while in the second test a U-shaped channel with cantilever sides and a simple cantilever wall were studied. All of these structures were chosen to be representative of typical designs. Dry medium-dense sand with relative density on the order of from 75% to 80% was used as backfill. Results obtained from the centrifuge experiments were subsequently used to develop and calibrate a two-dimensional, nonlinear, finite difference model built on the FLAC platform.

The centrifuge data consistently shows that for the height of structures considered herein, i.e. in the range of 20-30 ft, the maximum dynamic earth pressure increases with depth and can be reasonably approximated by a triangular distribution This suggests that the point of application of the resultant force of the dynamic earth pressure increment is approximately 1/3H above the base of the wall as opposed to 0.5-0.6 H recommended by most current design procedures. In general, the magnitude of the observed seismic earth pressures depends on the magnitude and intensity of shaking, the density of the backfill soil, and the type of the retaining structures. The computed values of seismic earth pressure coefficient (∆Kae) back calculated from the centrifuge data at the time of maximum dynamic wall moment suggest that for free standing cantilever retaining structures seismic earth pressures can be neglected at accelerations below 0.4 g. While similar conclusions and recommendations were made by Seed and Whitman (1970), their approach assumed that a wall designed to a reasonable static factor of safety should be able to resist seismic loads up 0.3 g. In the present study, experimental data suggest that seismic loads up to 0.4 g could be resisted by cantilever walls designed to an adequate factor of safety. This observation is consistent with the observations and analyses performed by Clough and Fragaszy (1977) and Fragaszy and Clough (1980) and Al-Atik and Sitar (2010) who concluded that conventionally designed cantilever walls with granular backfill could be reasonably expected to resist seismic loads at accelerations up to 0.4 g.

Finally, numerical models using FLAC finite difference code were quite successful and able to produce a reasonably good agreement with the results of the centrifuge experiments. However, while the finite difference models were able to capture the main aspects of the seismic response observed in the centrifuge experiments, the results of the analyses were highly sensitive to the selection of soil and interface parameters. Therefore, numerical models used for future designs should be carefully calibrated against experimental data in order to provide reliable results.

Main Content
For improved accessibility of PDF content, download the file to your device.
Current View