- Collaboration, The MAJORANA;
- Arnquist, IJ;
- III, FT Avignone;
- Barabash, AS;
- Barton, CJ;
- Bertrand, FE;
- Blalock, E;
- Bos, B;
- Busch, M;
- Buuck, M;
- Caldwell, TS;
- Chan, Y-D;
- Christofferson, CD;
- Chu, P-H;
- Clark, ML;
- Cuesta, C;
- Detwiler, JA;
- Drobizhev, A;
- Edwards, TR;
- Edwins, DW;
- Efremenko, Yu;
- Elliott, SR;
- Gilliss, T;
- Giovanetti, GK;
- Green, MP;
- Gruszko, J;
- Guinn, IS;
- Guiseppe, VE;
- Haufe, CR;
- Hegedus, RJ;
- Henning, R;
- Aguilar, D Hervas;
- Hoppe, EW;
- Hostiuc, A;
- Kim, I;
- Kouzes, RT;
- Lopez, AM;
- López-Castaño, JM;
- Martin, EL;
- Martin, RD;
- Massarczyk, R;
- Meijer, SJ;
- Mertens, S;
- Myslik, J;
- Oli, TK;
- Othman, G;
- Pettus, W;
- Poon, AWP;
- Radford, DC;
- Rager, J;
- Reine, AL;
- Rielage, K;
- Ruof, NW;
- Saykı, B;
- önert, S Sch;
- Stortini, MJ;
- Tedeschi, D;
- Varner, RL;
- Vasilyev, S;
- Wilkerson, JF;
- Willers, M;
- Wiseman, C;
- Xu, W;
- Yu, C-H;
- Zhu, BX
P-type point contact (PPC) HPGe detectors are a leading technology for rare
event searches due to their excellent energy resolution, low thresholds, and
multi-site event rejection capabilities. We have characterized a PPC detector's
response to $\alpha$ particles incident on the sensitive passivated and p+
surfaces, a previously poorly-understood source of background. The detector
studied is identical to those in the MAJORANA DEMONSTRATOR experiment, a search
for neutrinoless double-beta decay ($0
u\beta\beta$) in $^{76}$Ge. $\alpha$
decays on most of the passivated surface exhibit significant energy loss due to
charge trapping, with waveforms exhibiting a delayed charge recovery (DCR)
signature caused by the slow collection of a fraction of the trapped charge.
The DCR is found to be complementary to existing methods of $\alpha$
identification, reliably identifying $\alpha$ background events on the
passivated surface of the detector. We demonstrate effective rejection of all
surface $\alpha$ events (to within statistical uncertainty) with a loss of only
0.2% of bulk events by combining the DCR discriminator with previously-used
methods. The DCR discriminator has been used to reduce the background rate in
the $0
u\beta\beta$ region of interest window by an order of magnitude in the
MAJORANA DEMONSTRATOR, and will be used in the upcoming LEGEND-200 experiment.