Skip to main content
eScholarship
Open Access Publications from the University of California

UC Berkeley

UC Berkeley Electronic Theses and Dissertations bannerUC Berkeley

MR Shuffling: Accelerated Single-Scan Multi-Contrast Magnetic Resonance Imaging

Abstract

Magnetic resonance imaging (MRI) is an attractive medical imaging modality as it is non-invasive and does not involve ionizing radiation. Routine clinical MRI exams obtain MR images corresponding to different soft tissue contrast by performing multiple scans. When two-dimensional (2D) imaging is used, these scans are often repeated in other scanning planes. As a result, the number of scans comprising an MRI exam leads to prohibitively long exam times as compared to other medical imaging modalities such as computed tomography. Many approaches have been designed to accelerate the MRI acquisition while maintaining diagnostic quality.

One approach is to collect multiple measurements while the MRI signal is evolving due to relaxation. This enables a reduction in scan time, as fewer acquisition windows are needed to collect the same number of measurements. However, when the temporal aspect of the acquisition is left unmodeled, artifacts are likely to appear in the reconstruction. Most often, these artifacts manifest as image blurring. The effect depends on the acquisition parameters as well as the tissue relaxation itself, resulting in spatially varying blurring. The severity of the artifacts is directly related to the level of acceleration, and thus presents a tradeoff with scan time. The effect is amplified when imaging in three dimensions, severely limiting scan efficiency. Volumetric variants would be used if not for the blurring, as they are able to reconstruct images at isotropic resolution and support mutli-planar reformatting.

Another established acceleration technique, called parallel imaging, takes advantage of spatially sensitive receive coil arrays to collect multiple MRI measurements in parallel. Thus, the acquisition is shortened, and the reconstruction uses the spatial sensitivity information to recover the image. More recently, methods have been developed that leverage image structure such as sparsity and low rank to reduce the required number of samples for a well-posed reconstruction. Compressed sensing and its low rank extensions use these concepts to acquire incoherent measurements below the Nyquist rate. These techniques are especially suited to MRI, as incoherent measurements can be easily achieved through pseudo-random under-sampling. As the mechanisms behind parallel imaging and compressed sensing are fundamentally different, they can be combined to achieve even higher acceleration.

This dissertation proposes accelerated MRI acquisition and reconstruction techniques that account for the temporal dynamics of the MR signal. The methods build off of parallel imaging and compressed sensing to reduce scan time and flexibly model the temporal relaxation behavior. By randomly shuffling the sampling in the acquisition stage and imposing low rank constraints in the reconstruction stage, intrinsic physical parameters are modeled and their dynamics are recovered as multiple images of varying tissue contrast. Additionally, blurring artifacts are significantly reduced, as the temporal dynamics are accounted for in the reconstruction.

This dissertation first introduces T2 Shuffling, a volumetric technique that reduces blurring and reconstructs multiple T2-weighted image contrasts from a single acquisition. The method is integrated into a clinical hospital environment and evaluated on patients. Next, this dissertation develops a fast and distributed reconstruction for T2 Shuffling that achieves clinically relevant processing time latency. Clinical validation results are shown comparing T2 Shuffling as a single-sequence alternative to conventional pediatric knee MRI. Based off the compelling results, a fast targeted knee MRI using T2 Shuffling is implemented, enabling same-day access to MRI at one-third the cost compared to the conventional exam. To date, over 2,400 T2 Shuffling patient scans have been performed.

Continuing the theme of accelerated multi-contrast imaging, this dissertation extends the temporal signal model with T1-T2 Shuffling. Building off of T2 Shuffling, the new method additionally samples multiple points along the saturation recovery curve by varying the repetition time durations during the scan. Since the signal dynamics are governed by both T1 recovery and T2 relaxation, the reconstruction captures information about both intrinsic tissue parameters. As a result, multiple target synthetic contrast images are reconstructed, all from a single scan. Approaches for selecting the sequence parameters are provided, and the method is evaluated on in vivo brain imaging of a volunteer.

Altogether, these methods comprise the theme of MR Shuffling, and may open new pathways toward fast clinical MRI.

Main Content
For improved accessibility of PDF content, download the file to your device.
Current View