Skip to main content
eScholarship
Open Access Publications from the University of California

UCSF

UC San Francisco Previously Published Works bannerUCSF

Association of Cardiac Troponin T With Left Ventricular Structure and Function in CKD

Abstract

Background

Serum cardiac troponin T (cTnT) is associated with increased risk of heart failure and cardiovascular death in several population settings. We evaluated associations of cTnT levels with cardiac structural and functional abnormalities in a cohort of patients with chronic kidney disease (CKD) without heart failure.

Study design

Cross-sectional.

Setting & participants

Chronic Renal Insufficiency Cohort (CRIC; N=3,243).

Predictor

The primary predictor was cTnT level. Secondary predictors included demographic and clinical characteristics, hemoglobin level, high-sensitivity C-reactive protein level, and estimated glomerular filtration rate using cystatin C.

Outcomes

Echocardiography was used to determine left ventricular (LV) mass and LV systolic and diastolic function.

Measurements

Circulating cTnT was measured in stored sera using the highly sensitive assay. Logistic and linear regression models were used to examine associations of cTnT level with each echocardiographic outcome.

Results

cTnT was detectable in 2,735 (84%) persons; median level was 13.3 (IQR, 7.7-23.8) pg/mL. Compared with undetectable cTnT (<3.0 pg/mL), the highest quartile (23.9-738.7 pg/mL) was approximately 2 times as likely to have LV hypertrophy (OR, 2.43; 95% CI, 1.44-4.09) in the fully adjusted model. cTnT level had a more modest association with LV systolic dysfunction; as a log-linear variable, a significant association was present in the fully adjusted model (OR of 1.4 [95% CI, 1.2-1.7] per 1-log unit; P < 0.001). There was no significant independent association between cTnT level and LV diastolic dysfunction. When evaluated as a screening test, cTnT level functioned only modestly for LV hypertrophy and concentric hypertrophy detection (area under the curve, 0.64 for both), with weaker areas under the curve for the other outcomes.

Limitations

The presence of coronary artery disease was not formally assessed using either noninvasive or angiographic techniques in this study.

Conclusions

In this large CKD cohort without heart failure, detectable cTnT had a strong association with LV hypertrophy, a more modest association with LV systolic dysfunction, and no association with diastolic dysfunction. These findings indicate that circulating cTnT levels in patients with CKD are predominantly an indicator of pathologic LV hypertrophy.

Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.

Main Content
For improved accessibility of PDF content, download the file to your device.
Current View