- Main
Diagnostic accuracy of [18F]PSMA-1007 PET/CT in biochemical recurrence of prostate cancer.
Published Web Location
https://doi.org/10.1007/s00259-022-05693-0Abstract
AIM: Despite increasing use for the detection of biochemically recurrent prostate cancer (rPC), the diagnostic accuracy of positron emission tomography/computed tomography (PET/CT) with [18F]PSMA-1007 remains only partially investigated. The aim of this study was to determine the sensitivity (SE), specificity (SP), positive predictive value (PPV), and negative predictive value (NPV) for PC-local recurrence and metastases on a per region basis. MATERIALS AND METHODS: One hundred seventy-seven consecutive patients undergoing [18F]PSMA-1007 PET/CT for rPC were retrospectively analysed. Six body regions were defined: prostate fossa, pelvic lymph nodes (LN), retroperitoneal LN, supradiaphragmatic LN, bones, and soft tissue. A region was counted positive if at least one PSMA-positive lesion suspicious for PC was observed. Confirmation of a true-positive PSMA-avid lesion was defined as positive by histopathology, fall in serum prostate-specific antigen (PSA) (> 50%) after targeted therapy or confirmatory further CT, MRI, PET/CT, or bone scan imaging. Regions where additional imaging was able to confirm the absence of suspicious PC lesions or regions outside exclusively targeted RT with serum PSA decline (> 50%) were counted as true-negative regions. SE, SP, PPV, and NPV were calculated for all six regions. RESULTS: The overall PET-positivity rate was 91%. Conclusive follow-up for affirmation or refutation of a PSMA-positive lesion was available for 81/152 patients on a per region basis. In this subgroup, overall sensitivity, specificity, PPV, and NPV were 95% (CI: 0.90-0.98), 89% (CI: 0.83-0.93), 86% (0.80-0.90), and 96% (CI: 0.92-0.98), respectively. On a per region basis, PPV was 97% (CI: 0.83-0.99) for local recurrence, 93% (CI: 0.78-0.98) for pelvic LN, 87% (CI: 0.62-0.96) for retroperitoneal LN, 82% (CI: 0.52-0.95) for supradiaphragmatic LN, and 79% (0.65-0.89) for bone lesions. The number of solid organ metastases (n = 6) was too small for an accurate statistical analysis. CONCLUSION: The known high PET-positivity rate of [18F]PSMA-1007 PET/CT in rPC was confirmed, with corresponding high (> 90%) sensitivity and NPV on a per region basis. However, overall PPV was limited (86%), particularly for bone lesions (79%), which are a potential diagnostic weaknesses when using this tracer.
Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.
Main Content
Enter the password to open this PDF file:
-
-
-
-
-
-
-
-
-
-
-
-
-
-