Skip to main content
eScholarship
Open Access Publications from the University of California

UCSF

UC San Francisco Previously Published Works bannerUCSF

Late graft failure is rare after endovascular aneurysm repair using the Zenith stent graft in a cohort of high-risk patients

Abstract

Objective

Device-specific data on the long-term efficacy of endovascular aneurysm repair (EVAR) are limited by the constant evolution of stent graft design. Whereas some modifications, such as barb-mediated fixation, probably enhance durability, others, such as thin-walled fabric, are of less certain benefit. The purpose of this study was to examine 15 years of a single-center experience of EVAR using the Zenith stent graft (Cook Medical, Bloomington, Ind).

Methods

Retrospective analysis was conducted of 325 high-risk patients who underwent elective EVAR with Zenith stent grafts between October 1998 and December 2005 under a physician-sponsored investigational device exemption. Patients' charts and death registries were reviewed to identify late stent graft failures and causes of death. Late stent graft failures were defined as type I or type III endoleaks; enlarging aneurysm sac requiring revision; and limb kinking or occlusion, stent graft infection, renal artery occlusion, or aneurysm rupture occurring >30 days after the index procedure.

Results

The mean age at treatment was 75.9 ± 7.4 years, and 300 of 325 (92%) were men. The mean aneurysm diameter was 60 ± 9 mm, and the median main body stent graft diameter was 28 mm (range, 22-32 mm). During a median follow-up time of 5.6 years (interquartile range, 2.6-8.7 years), there were six (2%) aneurysm-related deaths caused by the following: one stent graft infection, one infection of a femoral-femoral bypass graft placed after limb occlusion, one infection of a stent graft placed to treat a type IB endoleak, and three aneurysm ruptures. There were 19 (6%) late stent graft failures occurring at a median time of 4.0 years (range, 39 days-14.6 years) after the procedure. Patients with late stent graft failure were more likely to have had impaired renal function (creatinine concentration ≥2 mg/dL; 21% vs 6%; P = .03) and less likely to have had cardiac disease (42% vs 67%; P = .04) at the time of the index procedure. There was no significant association between late stent graft failure and age, sex, aneurysm size, stent graft diameter, diabetes, smoking, or lung disease. Kaplan-Meier estimated overall survival was 60% at 5 years, 29% at 10 years, and 12% at 15 years. Kaplan-Meier estimated freedom from aneurysm-related mortality was 98% at 5 years, 97% at 10 years, and 97% at 15 years.

Conclusions

Late-occurring stent graft failures and aneurysm-related death are rare after EVAR using the Zenith stent graft, especially in high-risk patients whose comorbidities diminish life expectancy.

Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.

Main Content
For improved accessibility of PDF content, download the file to your device.
Current View