Skip to main content
eScholarship
Open Access Publications from the University of California

UCLA

UCLA Previously Published Works bannerUCLA

A sparse orthogonal collimator for small animal intensity‐modulated radiation therapy part I: Planning system development and commissioning

Published Web Location

https://doi.org/10.1002/mp.13872
Abstract

Purpose

To achieve more translatable preclinical research results, small animal irradiation needs to more closely simulate human radiotherapy. Although the clinical gold standard is intensity-modulated radiation therapy (IMRT), the direct translation of this method for small animals is impractical. In this study we describe the treatment planning system for a novel dose modulation device to address this challenge.

Methods

Using delineated target and avoidance structures, a rectangular aperture optimization (RAO) problem was formulated to penalize deviations from a desired dose distribution and limit the number of selected rectangular apertures. RAO was used to create IMRT plans with highly concave targets in the mouse brain, and the plan quality was compared to that using a hypothetical miniaturized multileaf collimator (MLC). RAO plans were also created for a realistic application of mouse whole liver irradiation and for a highly complex two-dimensional (2D) dose distribution as a proof-of-principle. Beam commissioning data, including output and off-axis factors and percent depth dose (PDD) curves, were acquired for our small animal irradiation system and incorporated into the treatment planning system. A plan post-processing step was implemented for aperture size-specific dose recalculation and aperture weighting reoptimization.

Results

The first RAO test case achieved highly conformal doses to concave targets in the brain, with substantially better dose gradient, conformity, and target dose homogeneity than the hypothetical miniaturized MLC plans. In the second test case, a highly conformal dose to the liver was achieved with significant sparing of the kidneys. RAO also successfully replicated a complex 2D dose distribution with three prescription dose levels. Energy spectra for field sizes 1 to 20 mm were calculated to match the measured PDD curves, with maximum and mean dose deviations of 4.47 ± 0.30% and 1.71 ± 0.18%. The final reoptimization of aperture weightings for the complex RAO test plan was able to reduce the maximum and mean dose deviations between the optimized and recalculated dose distributions from 10.3% to 6.6% and 4.0% to 2.8%, respectively.

Conclusions

Using the advanced optimization techniques, complex IMRT plans were achieved using a simple dose modulation device. Beam commissioning data were incorporated into the treatment planning process to more accurately predict the resulting dose distribution. This platform substantially reduces the gap in treatment plan quality between clinical and preclinical radiotherapy, potentially increasing the value and flexibility of small animal studies.

Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.

Main Content
For improved accessibility of PDF content, download the file to your device.
Current View