Real-Time Continuous Glucose Monitoring Among Participants in the T1D Exchange Clinic Registry
Published Web Location
https://doi.org/10.2337/dc14-0303Abstract
Objective
To assess the frequency of continuous glucose monitoring (CGM) device use, factors associated with its use, and the relationship of CGM with diabetes outcomes (HbA1c, severe hypoglycemia [SH], and diabetic ketoacidosis [DKA]).Research design and methods
Survey questions related to CGM device use 1 year after enrollment in the T1D Exchange clinic registry were completed by 17,317 participants. Participants were defined as CGM users if they indicated using real-time CGM during the prior 30 days.Results
Nine percent of participants used CGM (6% of children <13 years old, 4% of adolescents 13 to <18 years, 6% of young adults 18 to <26 years, and 21% of adults ≥26 years). CGM use was more likely with higher education, higher household income, private health insurance, longer duration of diabetes, and use of insulin pump (P < 0.01 all factors). CGM use was associated with lower HbA1c in children (8.3% vs. 8.6%, P < 0.001) and adults (7.7% vs. 7.9%, P < 0.001). In adults, more frequent use of CGM (≥6 days/week) was associated with lower mean HbA1c. Only 27% of users downloaded data from their device at least once per month, and ≤15% of users reported downloading their device at least weekly. Among participants who used CGM at baseline, 41% had discontinued within 1 year.Conclusions
CGM use is uncommon but associated with lower HbA1c in some age-groups, especially when used more frequently. Factors associated with discontinuation and infrequent use of retrospective analysis of CGM data should be considered in developing next-generation devices and education on CGM use.Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.