Emergency Department Management of Chest Pain With a High-Sensitivity Troponin-Enabled 0/1-Hour Rule-Out Algorithm
Abstract
Objectives
The analytical sensitivity of high-sensitivity cardiac troponin T (hsTnT) assays has enabled rapid myocardial infarction rule-out algorithms for emergency department (ED) presentations. Few studies have analyzed the real-world impact of hsTnT algorithms on outcomes and operations.Methods
Comparison of ED length of stay (LOS) and 30-day outcomes (return to ED, inpatient admission, and mortality) for patients presenting with chest pain during 2 separate 208-day periods using a 0/1-hour hsTnT-enabled algorithm or fourth-generation TnT.Results
Discharge, 30-day readmission, and 30-day mortality rates were not significantly different with fourth-generation TnT vs hsTnT. Thirty-day return rates were significantly decreased with hsTnT (17.4% vs 14.9%; P < .01). For encounters with TnT measured at least twice and resulting in discharge, median ED LOS decreased by 61 minutes with the use of hsTnT (488 vs 427 minutes; P < .0001). Median time between first and second TnT results decreased by 82 minutes with hsTnT (202 vs 120 minutes; P < .0001), suggesting that the 0/1-hour algorithm was incompletely adopted.Conclusions
Implementation of the hsTnT algorithm was associated with decreased 30-day return rates and decreased ED LOS for a subset of patients, despite incomplete adoption of the 0/1-hour algorithm.Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.
Main Content
For improved accessibility of PDF content, download the file to your device.
Enter the password to open this PDF file:
File name:
-
File size:
-
Title:
-
Author:
-
Subject:
-
Keywords:
-
Creation Date:
-
Modification Date:
-
Creator:
-
PDF Producer:
-
PDF Version:
-
Page Count:
-
Page Size:
-
Fast Web View:
-
Preparing document for printing…
0%