Skip to main content
eScholarship
Open Access Publications from the University of California

UC San Diego

UC San Diego Previously Published Works bannerUC San Diego

Reliability of mismatch negativity event-related potentials in a multisite, traveling subjects study.

Abstract

Objective

To determine the optimal methods for measuring mismatch negativity (MMN), an auditory event-related potential (ERP), and quantify sources of MMN variance in a multisite setting.

Methods

Reliability of frequency, duration, and double (frequency + duration) MMN was determined from eight traveling subjects, tested on two occasions at eight laboratory sites. Deviant-specific variance components were estimated for MMN peak amplitude and latency measures using different ERP processing methods. Generalizability (G) coefficients were calculated using two-facet (site and occasion), fully-crossed models and single-facet (occasion) models within each laboratory to assess MMN reliability.

Results

G-coefficients calculated from two-facet models indicated fair (0.4 < G<=0.6) duration MMN reliability at electrode Fz, but poor (G < 0.4) double and frequency MMN reliability. Single-facet G-coefficients averaged across laboratory resulted in improved reliability (G > 0.5). MMN amplitude reliability was greater than latency reliability, and reliability with mastoid referencing significantly outperformed nose-referencing.

Conclusions

EEG preprocessing methods have an impact on the reliability of MMN amplitude. Within site MMN reliability can be excellent, consistent with prior single site studies.

Significance

With standardized data collection and ERP processing, MMN can be reliably obtained in multisite studies, providing larger samples sizeswithin rare patient groups.

Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.

Main Content
For improved accessibility of PDF content, download the file to your device.
Current View