Comparison of Metallic Foreign Body Removal between Dynamic Ultrasound and Static Radiography in a Pigs’ Feet Model

Abstract

Introduction: We compared the immediate cosmetic outcome of metallic foreign-body removal by emergency medicine (EM) residents with ultrasound guidance and conventional radiography.

Methods: This single-blinded, randomized, crossover study evaluated the ability of EM residents to remove metallic pins embedded in pigs’ feet. Before the experiment, we embedded 1.5-cm metallic pins into numbered pigs’ feet. We randomly assigned 14 EM residents to use either ultrasound or radiography to help remove the foreign body. Residents had minimal ultrasound experience. After a brief lecture, we provided residents with a scalpel, laceration kit, a bedside portable ultrasound machine, nipple markers, paper clips, a dedicated radiograph technician, and radiograph machine 20 feet away. After removal, 3 board-certified emergency physicians, who were blinded to the study group, evaluated the soft-tissue model by using a standardized form. They recorded incision length and cosmetic appearance on the Visual Analogue Scale.

Results: In total, 28 foreign bodies were removed. No significant difference in the time of removal (P¼ 0.12), cosmetic appearance (P ¼ 0.96), or incision length (P ¼ 0.76) was found.

Conclusion: This study showed no difference between bedside ultrasound and radiography in assisting EM residents with metallic foreign-body removal from soft tissue. No significant difference was found in removal time or cosmetic outcome when comparing ultrasound with radiography.

Main Content
For improved accessibility of PDF content, download the file to your device.
Current View