Diagnostic Performance of 18F-DCFPyL-PET/CT in Men with Biochemically Recurrent Prostate Cancer: Results from the CONDOR Phase III, Multicenter StudyCONDOR Trial
- Morris, Michael J;
- Rowe, Steven P;
- Gorin, Michael A;
- Saperstein, Lawrence;
- Pouliot, Frédéric;
- Josephson, David;
- Wong, Jeffrey YC;
- Pantel, Austin R;
- Cho, Steve Y;
- Gage, Kenneth L;
- Piert, Morand;
- Iagaru, Andrei;
- Pollard, Janet H;
- Wong, Vivien;
- Jensen, Jessica;
- Lin, Tess;
- Stambler, Nancy;
- Carroll, Peter R;
- Siegel, Barry A;
- Group, CONDOR Study
- et al.
Published Web Location
https://doi.org/10.1158/1078-0432.ccr-20-4573Abstract
Purpose
Current FDA-approved imaging modalities are inadequate for localizing prostate cancer biochemical recurrence (BCR). 18F-DCFPyL is a highly selective, small-molecule prostate-specific membrane antigen-targeted PET radiotracer. CONDOR was a prospective study designed to determine the performance of 18F-DCFPyL-PET/CT in patients with BCR and uninformative standard imaging.Experimental design
Men with rising PSA ≥0.2 ng/mL after prostatectomy or ≥2 ng/mL above nadir after radiotherapy were eligible. The primary endpoint was correct localization rate (CLR), defined as positive predictive value with an additional requirement of anatomic lesion colocalization between 18F-DCFPyL-PET/CT and a composite standard of truth (SOT). The SOT consisted of, in descending priority (i) histopathology, (ii) subsequent correlative imaging findings, or (iii) post-radiation PSA response. The trial was considered a success if the lower bound of the 95% confidence interval (CI) for CLR exceeded 20% for two of three 18F-DCFPyL-PET/CT readers. Secondary endpoints included change in intended management and safety.Results
A total of 208 men with a median baseline PSA of 0.8 ng/mL (range: 0.2-98.4 ng/mL) underwent 18F-DCFPyL-PET/CT. The CLR was 84.8%-87.0% (lower bound of 95% CI: 77.8-80.4). A total of 63.9% of evaluable patients had a change in intended management after 18F-DCFPyL-PET/CT. The disease detection rate was 59% to 66% (at least one lesion detected per patient by 18F-DCFPyL-PET/CT by central readers).Conclusions
Performance of 18F-DCFPyL-PET/CT achieved the study's primary endpoint, demonstrating disease localization in the setting of negative standard imaging and providing clinically meaningful and actionable information. These data further support the utility of 18F-DCFPyL-PET/CT to localize disease in men with recurrent prostate cancer.See related commentary by True and Chen, p. 3512.Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.
Main Content
For improved accessibility of PDF content, download the file to your device.
Enter the password to open this PDF file:
File name:
-
File size:
-
Title:
-
Author:
-
Subject:
-
Keywords:
-
Creation Date:
-
Modification Date:
-
Creator:
-
PDF Producer:
-
PDF Version:
-
Page Count:
-
Page Size:
-
Fast Web View:
-
Preparing document for printing…
0%