Skip to main content
eScholarship
Open Access Publications from the University of California

UCLA

UCLA Previously Published Works bannerUCLA

Evaluation of Spatial Attentive Deep Learning for Automatic Placental Segmentation on Longitudinal MRI

Abstract

Background

Automated segmentation of the placenta by MRI in early pregnancy may help predict normal and aberrant placenta function, which could improve the efficiency of placental assessment and the prediction of pregnancy outcomes. An automated segmentation method that works at one gestational age may not transfer effectively to other gestational ages.

Purpose

To evaluate a spatial attentive deep learning method (SADL) for automated placental segmentation on longitudinal placental MRI scans.

Study type

Prospective, single-center.

Subjects

A total of 154 pregnant women who underwent MRI scans at both 14-18 weeks of gestation and at 19-24 weeks of gestation, divided into training (N = 108), validation (N = 15), and independent testing datasets (N = 31).

Field strength/sequence

A 3 T, T2-weighted half Fourier single-shot turbo spin-echo (T2-HASTE) sequence.

Assessment

The reference standard of placental segmentation was manual delineation on T2-HASTE by a third-year neonatology clinical fellow (B.L.) under the supervision of an experienced maternal-fetal medicine specialist (C.J. with 20 years of experience) and an MRI scientist (K.S. with 19 years of experience).

Statistical tests

The three-dimensional Dice similarity coefficient (DSC) was used to measure the automated segmentation performance compared to the manual placental segmentation. A paired t-test was used to compare the DSCs between SADL and U-Net methods. A Bland-Altman plot was used to analyze the agreement between manual and automated placental volume measurements. A P value < 0.05 was considered statistically significant.

Results

In the testing dataset, SADL achieved average DSCs of 0.83 ± 0.06 and 0.84 ± 0.05 in the first and second MRI, which were significantly higher than those achieved by U-Net (0.77 ± 0.08 and 0.76 ± 0.10, respectively). A total of 6 out of 62 MRI scans (9.6%) had volume measurement differences between the SADL-based automated and manual volume measurements that were out of 95% limits of agreement.

Data conclusions

SADL can automatically detect and segment the placenta with high performance in MRI at two different gestational ages.

Level of evidence

4 TECHNICAL EFFICACY STAGE: 2.

Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.

Main Content
For improved accessibility of PDF content, download the file to your device.
Current View