Skip to main content
Download PDF
- Main
CT ventilation functional image-based IMRT treatment plans are comparable to SPECT ventilation functional image-based plans
Published Web Location
https://doi.org/10.1016/j.radonc.2016.02.019Abstract
Purpose
To investigate the hypothesis that CT ventilation functional image-based IMRT plans designed to avoid irradiating highly-functional lung regions are comparable to single-photon emission CT (SPECT) ventilation functional image-based plans.Methods and materials
Three IMRT plans were created for eight thoracic cancer patients using: (1) CT ventilation functional images, (2) SPECT ventilation functional images, and (3) anatomic images (no functional images). CT ventilation images were created by deformable image registration of 4D-CT image data sets and quantitative analysis. The resulting plans were analyzed for the relationship between the deviations of CT-functional plan metrics from anatomic plan metrics (ΔCT-anatomic) and those of SPECT-functional plans (ΔSPECT-anatomic), and moreover for agreements of various metrics between the CT-functional and SPECT-functional plans.Results
The relationship between ΔCT-anatomic and ΔSPECT-anatomic was strong (e.g., R=0.94; linear regression slope 0.71). The average differences and 95% limits of agreement between the CT-functional and SPECT-functional plan metrics (except for monitor units) for various structures were mostly less than 1% and 2%, respectively.Conclusions
This study demonstrated a reasonable agreement between the CT ventilation functional image-based IMRT plans and SPECT-functional plans, suggesting the potential for CT ventilation imaging to serve as a surrogate for SPECT ventilation in functional image-guided radiotherapy.Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.