Direct Attenuation Correction Using Deep Learning for Cardiac SPECT: A Feasibility Study

Abstract

Dedicated cardiac SPECT scanners with cadmium-zinc-telluride cameras have shown capabilities for shortened scan times or reduced radiation doses, as well as improved image quality. Since most dedicated scanners do not have integrated CT, image quantification with attenuation correction (AC) is challenging and artifacts are routinely encountered in daily clinical practice. In this work, we demonstrated a direct AC technique using deep learning (DL) for myocardial perfusion imaging (MPI). Methods: In an institutional review board-approved retrospective study, 100 cardiac SPECT/CT datasets with 99mTc-tetrofosmin, obtained using a scanner specifically with a small field of view, were collected at the Yale New Haven Hospital. A convolutional neural network was used for generating DL-based attenuation-corrected SPECT (SPECTDL) directly from noncorrected SPECT (SPECTNC) without undergoing an additional image reconstruction step. The accuracy of SPECTDL was evaluated by voxelwise and segmentwise analyses against the reference, CT-based AC (SPECTCTAC), using the 17-segment myocardial model of the American Heart Association. Polar maps of representative (best, median, and worst) cases were visually compared to illustrate potential benefits and pitfalls of the DL approach. Results: The voxelwise correlations with SPECTCTAC were 92.2% ± 3.7% (slope, 0.87; R2 = 0.81) and 97.7% ± 1.8% (slope, 0.94; R2 = 0.91) for SPECTNC and SPECTDL, respectively. The segmental errors of SPECTNC scattered from -35% to 21% (P < 0.001), whereas the errors of SPECTDL stayed mostly within ±10% (P < 0.001). The average segmental errors (mean ± SD) were -6.11% ± 8.06% and 0.49% ± 4.35% for SPECTNC and SPECTDL, respectively. The average absolute segmental errors were 7.96% ± 6.23% and 3.31% ± 2.87% for SPECTNC and SPECTDL, respectively. Review of polar maps revealed successful reduction of attenuation artifacts; however, the performance of SPECTDL was not consistent for all subjects, likely because of different amounts of attenuation and different uptake patterns. Conclusion: We demonstrated the feasibility of direct AC using DL for SPECT MPI. Overall, our DL approach reduced attenuation artifacts substantially compared with SPECTNC, justifying further studies to establish safety and consistency for clinical applications in stand-alone SPECT systems suffering from attenuation artifacts.

Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.

Main Content
For improved accessibility of PDF content, download the file to your device.
Current View