Skip to main content
Download PDF
- Main
Identifying predictors of on-table adaptation for pancreas stereotactic body radiotherapy (SBRT)
Published Web Location
https://doi.org/10.1016/j.ctro.2023.100603Abstract
Purpose
To identify any clinical or dosimetric parameters that predict which individuals may benefit from on-table adaptation during pancreas stereotactic body radiotherapy (SBRT) with MRI-guided radiotherapy.Methods and materials
This was a retrospective study of patients undergoing MRI-guided SBRT from 2016 to 2022. Pre-treatment clinical variables and dosimetric parameters on the patient's simulation scan were recorded for each SBRT course, and their ability to predict for on-table adaptation was analyzed using ordinal logistic regression. The outcome measure was number of fractions adapted.Results
Sixty-three SBRT courses consisting of 315 fractions were analyzed. Median prescription dose was 40 Gy in five fractions (range, 33-50 Gy); 52% and 48% of courses were prescribed ≤40 Gy and >40 Gy, respectively. The median minimum dose delivered to 95% (D95) of the gross tumor volume (GTV) and planning target volume (PTV) was 40.1 Gy and 37.0 Gy, respectively. Median number of fractions adapted per course was three, with 58% (183 out of 315) total fractions adapted. On univariable analysis, the prescription dose (>40 Gy vs ≤40 Gy), GTV volume, stomach V20 and V25, duodenum V20 and dose maximum, large bowel V33 and V35, GTV dose minimum, PTV dose minimum, and gradient index were significant determinants for adaptation (all p < 0.05). On multivariable analysis, only the prescription dose was significant (adjusted odds ratio 19.7, p = 0.005), but did not remain significant after multiple test correction (p = 0.08).Conclusions
The likelihood of needing on-table adaptation could not be reliably predicted a priori using pre-treatment clinical characteristics, dosimetry to nearby organs at risk, or other dosimetric parameters based on the patient's anatomy at the time of simulation, suggesting the critical importance of day-to-day variations in anatomy and increasing access to adaptive technology for pancreas SBRT. A higher (ablative) prescription dose was associated with increased use of adaptation.Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.
Main Content
For improved accessibility of PDF content, download the file to your device.
Enter the password to open this PDF file:
File name:
-
File size:
-
Title:
-
Author:
-
Subject:
-
Keywords:
-
Creation Date:
-
Modification Date:
-
Creator:
-
PDF Producer:
-
PDF Version:
-
Page Count:
-
Page Size:
-
Fast Web View:
-
Preparing document for printing…
0%