- Zhou, Jiejie;
- Zhang, Yang;
- Chang, Kai‐Ting;
- Lee, Kyoung Eun;
- Wang, Ouchen;
- Li, Jiance;
- Lin, Yezhi;
- Pan, Zhifang;
- Chang, Peter;
- Chow, Daniel;
- Wang, Meihao;
- Su, Min‐Ying
Background
Computer-aided methods have been widely applied to diagnose lesions detected on breast MRI, but fully-automatic diagnosis using deep learning is rarely reported.Purpose
To evaluate the diagnostic accuracy of mass lesions using region of interest (ROI)-based, radiomics and deep-learning methods, by taking peritumor tissues into consideration.Study type
Retrospective.Population
In all, 133 patients with histologically confirmed 91 malignant and 62 benign mass lesions for training (74 patients with 48 malignant and 26 benign lesions for testing).Field strength/sequence
3T, using the volume imaging for breast assessment (VIBRANT) dynamic contrast-enhanced (DCE) sequence.Assessment
3D tumor segmentation was done automatically by using fuzzy-C-means algorithm with connected-component labeling. A total of 99 texture and histogram parameters were calculated for each case, and 15 were selected using random forest to build a radiomics model. Deep learning was implemented using ResNet50, evaluated with 10-fold crossvalidation. The tumor alone, smallest bounding box, and 1.2, 1.5, 2.0 times enlarged boxes were used as inputs.Statistical tests
The malignancy probability was calculated using each model, and the threshold of 0.5 was used to make a diagnosis.Results
In the training dataset, the diagnostic accuracy was 76% using three ROI-based parameters, 84% using the radiomics model, and 86% using ROI + radiomics model. In deep learning using the per-slice basis, the area under the receiver operating characteristic (ROC) was comparable for tumor alone, smallest and 1.2 times box (AUC = 0.97-0.99), which were significantly higher than 1.5 and 2.0 times box (AUC = 0.86 and 0.71, respectively). For per-lesion diagnosis, the highest accuracy of 91% was achieved when using the smallest bounding box, and that decreased to 84% for tumor alone and 1.2 times box, and further to 73% for 1.5 times box and 69% for 2.0 times box. In the independent testing dataset, the per-lesion diagnostic accuracy was also the highest when using the smallest bounding box, 89%.Data conclusion
Deep learning using ResNet50 achieved a high diagnostic accuracy. Using the smallest bounding box containing proximal peritumor tissue as input had higher accuracy compared to using tumor alone or larger boxes.Level of evidence
3 Technical Efficacy: Stage 2.