- Chintam, Kavitha;
- Gerhardt, Michael R;
- Baker, Andrew M;
- Richard, Derek;
- Wilson, Mahlon S;
- Flesner, James Raymond;
- Rockward, Tommy;
- Hussey, Daniel S;
- LaManna, Jacob M;
- Jacobson, David L;
- Rau, Jon;
- Weber, Adam Z;
- Borup, Rod L
A small microwatt fuel cell stack with 8 cells was designed, fabricated, and tested for passive operation with pure H2 and O2 to provide continuous power for multiple decades with uncontrolled fluctuating ambient conditions. The stack was designed to operate with dead ended gas flows with water removal via passive membrane diffusion to notches in the bipolar plates. Two stacks with active areas of 0.2 cm2, one with 200 nm of membrane and the other with 400 urn, were assembled and tested at varying temperatures and current conditions. Temperatures ranged -55 °C to 70 °C, with focus on the lower temperatures. Factors affecting water production and removal included temperature, gas crossover, and membrane thickness. Currents were applied from 16 uA to 10 mA after the cells were stabilized at temperature, followed by a period of drying to observe water transport to the external peripheries of the cell. A two-dimensional multiphysics model was developed to further explore the water management system in varying conditions.