Skip to main content
eScholarship
Open Access Publications from the University of California

UC San Diego

UC San Diego Previously Published Works bannerUC San Diego

Diagnostic Accuracy of Preoperative Gadoxetic Acid–enhanced 3-T MR Imaging for Malignant Liver Lesions by Using Ex Vivo MR Imaging–matched Pathologic Findings as the Reference Standard

Published Web Location

https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4962530/pdf/nihms802582.pdf
No data is associated with this publication.
Abstract

Purpose

To determine per-lesion sensitivity and positive predictive value (PPV) of gadoxetic acid-enhanced 3-T magnetic resonance (MR) imaging for the diagnosis of malignant lesions by using matched (spatially correlated) hepatectomy pathologic findings as the reference standard. Materials and

Methods

In this prospective, institutional review board-approved, HIPAA-compliant study, 20 patients (nine men, 11 women; mean age, 59 years) with malignant liver lesions who gave written informed consent underwent preoperative gadoxetic acid-enhanced 3-T MR imaging for surgical planning. Two image sets were independently analyzed by three readers to detect liver lesions (set 1 without and set 2 with hepatobiliary phase [HBP] images). Hepatectomy specimen ex vivo MR imaging assisted in matching gadoxetic acid-enhanced 3-T MR imaging findings with pathologic findings. Interreader agreement was assessed by using the Cohen κ coefficient. Per-lesion sensitivity and PPV were calculated.

Results

Cohen κ values were 0.64-0.76 and 0.57-0.84, and overall per-lesion sensitivity was 45% (42 of 94 lesions) to 56% (53 of 94 lesions) and 58% (55 of 94 lesions) to 64% (60 of 94 lesions) for sets 1 and 2, respectively. The addition of HBP imaging did not affect interreader agreement but significantly improved overall sensitivity for one reader (P < .05) and almost for another (P = .05). Sensitivity for 0.2-0.5-cm lesions was 0% (0 of 26 lesions) to 8% (two of 26 lesions) for set 1 and 4% (one of 26 lesions) to 12% (three of 26 lesions) for set 2. Sensitivity for 0.6-1.0-cm lesions was 28% (nine of 32 lesions) to 59% (19 of 32 lesions) for set 1 and 66% (21 of 32 lesions) to 69% (22 of 32 lesions) for set 2. Sensitivity for lesions at least 1.0 cm in diameter was at least 81% (13 of 16 lesions) for set 1 and was not improved for set 2. PPV was 98% (56 of 57 lesions) to 100% (60 of 60 lesions) for all readers without differences between image sets or lesion size.

Conclusion

Gadoxetic acid-enhanced 3-T MR imaging provides high per-lesion sensitivity and PPV for preoperative malignant liver lesion detection overall, although sensitivity for 0.2-0.5-cm malignant lesions is poor.