Purpose
To compare onset times of glaucoma progression among different glaucoma tests: disc photography (DP), visual field (VF) testing, 2-dimensional (2D) retinal nerve fiber layer (RNFL) thickness, and 3-dimensional (3D) spectral-domain (SD) OCT neuroretinal rim measurements.Design
Prospective, longitudinal cohort study.Participants
One hundred twenty-four eyes of 124 patients with open-angle glaucoma.Methods
Over a 5-year period, 124 patients with open-angle glaucoma underwent yearly DP, VF testing, SD OCT RNFL thickness scans, and optic nerve volume scans (Spectralis; Heidelberg Engineering), all performed on the same day. From high-density optic nerve volume scans, custom-built software calculated the minimum distance band (MDB) thickness, a 3D neuroretinal rim parameter. Patients were classified as glaucoma progressors or nonglaucoma progressors using event-based analysis. Progression by DP and VF testing occurred when 3 masked glaucoma specialists unanimously concurred. Progression by RNFL and MDB thickness occurred if change of more than test-retest variability was observed. Kaplan-Meier curves were constructed to analyze time-to-progression data. Kappa Coefficients were used to measure agreement of progressing eyes among methods.Main outcome measures
Time to glaucoma progression among all 4 methods.Results
Global MDB thickness detected glaucoma progression in the highest percentage of eyes (52.4%) compared with DP (16.1%; P < 0.001) and global RNFL thickness (15.3%; P < 0.001). Global MDB thickness detected glaucoma progression earlier than either DP (23 months vs. 44 months; P < 0.001) or global RNFL thickness (23 months vs. 33 months; P < 0.001). Among MDB progressing eyes, 46.2% were confirmed simultaneously or later by other conventional methods. Agreement of glaucoma-progressing eyes for all 4 methods in paired fashion were slight to fair (κ = 0.095-0.300).Conclusions
High-density 3D SD OCT neuroretinal rim measurements detected glaucoma progression approximately 1 to 2 years earlier compared with current clinically available structural tests (i.e., DP and 2D RNFL thickness measurements).Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.
Main Content
For improved accessibility of PDF content, download the file to your device.
Enter the password to open this PDF file:
File name:
-
File size:
-
Title:
-
Author:
-
Subject:
-
Keywords:
-
Creation Date:
-
Modification Date:
-
Creator:
-
PDF Producer:
-
PDF Version:
-
Page Count:
-
Page Size:
-
Fast Web View:
-
Preparing document for printing…
0%