Piezoelectric Micromachined Ultrasonic Transducers for Human-Machine Interfaces
- Xia, Fan
- Advisor(s): Lin, Liwei
Abstract
Piezoelectric micromachined ultrasonic transducers (pMUTs) have small footprints, low power consumption, and ease of integration with front-end electronics, but their relatively low acoustic pressure remains a major challenge for various applications. This dissertation focuses on schemes to enhance the acoustic output of pMUTs and explores their potential applications in human-machine interfaces.Potassium sodium niobate (KNN), which features a high piezoelectric coefficient and a relatively low dielectric constant, has been utilized to improve acoustic transmission under low driving voltages together with comprehensive studies on the design principles, equivalent circuit model, and simulation. Prototype dual-electrode devices with circular unimorph diaphragms have been fabricated and characterized in electrical, mechanical, and acoustic domains. Results show enhanced electromechanical coupling factors, large mechanical vibration displacements and velocities, as well as improved acoustic outputs. A measured transmission sensitivity of 105.5 dB/V at 10 cm has been achieved, which is 5-10 times higher than those of AlN-based pMUTs at similar frequencies. The pulse-echo characterization also demonstrates good transceiving performance with clear echo signals up to 2.82 m.Various non-contact acoustic human-machine interface applications have been explored, including a haptic and a thermal actuation system. The mid-air haptic interface uses a 15×15 KNN pMUT array with a resonant frequency of 92.4 kHz to achieve a superior transmission pressure of 2900 Pa at 15 mm. The resulting transmitting sensitivity of 120.8 Pa/cm2 per volt is at least two times greater than those of previously reported AlN pMUTs at a similar frequency. Ultrasound-induced non-contact tactile stimulation on human palms has been realized by modulating ultrasound waves to a lower frequency within the human perception range. In another work, a mid-air thermal actuation system is developed to deliver non-contact thermal stimulation by transmitting ultrasound to a fabric for acoustic energy absorption. Results show a focal pressure of 1970 Pa by a pMUT array at a resonant frequency of 97.6 kHz to realize a fabric temperature rise of 7.5℃ within 320 seconds. The potential for thermal stimulation is evaluated through volunteer tests. These findings highlight the promise of air-coupled pMUT arrays with high acoustic pressure and compact form factors for actuation applications.A wearable health sensor for continuous blood pressure monitoring is presented using a bimorph AlN pMUT liner array. The signal degradation due to sensor-artery misalignment and the effectiveness of beam steering to mitigate these issues are investigated. Simulation results show that beam steering can broaden the field of view by 400% and maintain more than 60% of the signal strength with a misalignment up to 5 mm. Artery localization is achieved by analyzing the product of echo amplitudes from the anterior and posterior arterial walls, and the dynamic arterial motion is evaluated using phase shift information. A prototype system is experimentally validated on a volunteer’s upper arm to extract artery diameter variations, and the blood pressure is derived through cuff-based calibration. These results advance the field of non-invasive cardiovascular health monitoring using the pMUT technology.