Skip to main content
eScholarship
Open Access Publications from the University of California

Angiographic and intravascular ultrasound predictors of in-stent restenosis.

  • Author(s): Kasaoka, S
  • Tobis, JM
  • Akiyama, T
  • Reimers, B
  • Di Mario, C
  • Wong, ND
  • Colombo, A
  • et al.
Abstract

OBJECTIVES:This study was performed to determine predictors of in-stent restenosis from a high volume, single-center practice. BACKGROUND:Intracoronary stents have been shown to reduce the restenosis rate as compared with balloon angioplasty, but in-stent restenosis continues to be an important clinical problem. METHODS:Between April 1993 and March 1997, 1,706 patients with 2,343 lesions were treated with a variety of intracoronary stents. The majority of stents were placed with high pressure balloon inflations and intravascular ultrasound (IVUS) guidance. Angiographic follow-up was obtained in 1,173 patients with 1,633 lesions (70%). Clinical, angiographic and IVUS variables were prospectively recorded and analyzed by univariate and multivariate models for the ability to predict the occurrence of in-stent restenosis defined as a diameter stenosis > or =50%. RESULTS:In-stent restenosis was angiographically documented in 282 patients with 409 lesions (25%). The restenosis group had a significantly longer total stent length, smaller reference lumen diameter, smaller final minimal lumen diameter (MLD) by angiography and smaller stent lumen cross-sectional area (CSA) by IVUS. In lesions where IVUS guidance was used, the restenosis rate was 24% as compared with 29% if IVUS was not used (p < 0.05). By multivariate logistic regression analysis, longer total stent length, smaller reference lumen diameter and smaller final MLD were strong predictors of in-stent restenosis. In lesions with IVUS guidance, IVUS stent lumen CSA was a better independent predictor than the angiographic measurements. CONCLUSIONS:Achieving an optimal stent lumen CSA by using IVUS guidance during the procedure and minimizing the total stent length may reduce in-stent restenosis.

Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.

Main Content
Current View