Skip to main content
eScholarship
Open Access Publications from the University of California

UC Irvine

UC Irvine Electronic Theses and Dissertations bannerUC Irvine

Precision Methods for Long-Baseline Neutrino Experiments: Flux Constraints, Statistical Inference, and Liquid-Argon Detector Monitoring

Abstract

Long-baseline neutrino oscillation experiments use measurements from near and far detectors to study neutrino flavor transitions and determine oscillation parameters. NOvA uses the NuMI neutrino beam at Fermilab to measure muon-neutrino disappearance and electron neutrino appearance, together with the corresponding antineutrino oscillation channels. DUNE is a next-generation long-baseline experiment that will use liquid-argon time projection chambers to make precision measurements of neutrino oscillations. This dissertation presents three studies: a neutrino flux constraint using neutrino–electron elastic scattering in the NOvA Near Detector, an accelerated Feldman–Cousins method using Gaussian processes for neutrino oscillation analyses, and contributions to liquid-argon purity monitoring for ProtoDUNE.The first study constrains the neutrino flux using neutrino–electron elastic scattering in the NOvA Near Detector. The neutrino–electron elastic scattering cross section can be precisely predicted using electroweak theory, making this interaction suitable for neutrino flux measurements. The scattered electron travels nearly along the incident neutrino direction,  providing a useful signature for identifying signal events. Using an exposure of 1.38 × 1021 protons on target (POT), we select 827 neutrino–electron scattering candidates and estimate a signal yield of 740.1 ± 30.2 (stat.) events after background subtraction. We then use the reconstructed energy spectrum of the selected electron candidates to constrain an ensemble of 100 PPFX flux universes through Bayesian reweighting, incorporating statistical and non-PPFX systematic uncertainties. The resulting constraint reduces the fractional uncertainty on the integrated muon-neutrino flux from 8.1% to 4.0%, with a posterior mean of 126.4 νµ cm−2/(1010 POT). The second study develops an accelerated Feldman–Cousins method using Gaussian processes for NOvA neutrino oscillation analyses. Standard asymptotic approximations for likelihood-ratio test statistics may not provide accurate confidence intervals in the presence of physical parameter boundaries, degeneracies, or limited event statistics. The Feldman– Cousins method uses pseudo-experiments to determine the test-statistic distribution at each point in parameter space. However, generating enough pseudo-experiments requires many likelihood fits and is computationally expensive. GP–FC reduces this cost by using Gaussian process regression to approximate the significance surface and identify regions of parameter space that require additional pseudo-experiments. We parallelize independent likelihood fits using MPI and the DIY framework, with dynamic load balancing and checkpointing to support large-scale calculations. The intersection-over-union values for iterations 0, 2, and 4 are (96.56 ± 0.05)%, (97.88 ± 0.05)%, and (98.14 ± 0.05)%, respectively, when compared with the reference Feldman–Cousins confidence region. The third study describes contributions to liquid-argon purity monitoring for the DUNE detector development program. In liquid-argon time projection chambers, electronegative impurities capture drifting ionization electrons and reduce the charge reaching the readout. Purity monitors measure this charge attenuation to determine the electron lifetime in liquid argon. This dissertation describes contributions to the design, construction, operation, waveform analysis, and calibration of purity monitors used in ProtoDUNE. During high-purity operation of ProtoDUNE-SP, purity monitors in the upper and middle regions measured electron lifetimes exceeding 70 ms, while monitors in the lower region measured lifetimes of at least 30 ms. The dissertation also presents subsequent work on instrumentation, calibration, and automated monitoring for ProtoDUNE-HD.