Skip to main content
Download PDF
- Main
The effect of weight, body mass index, age, sex , and race on plasma concentrations of subcutaneous sumatriptan: a pooled analysis
Published Web Location
https://doi.org/10.2147/cpaa.s108966Abstract
Objective/background
Factors such as body size (weight and body mass index [BMI]), age, sex, and race might influence the clinical response to sumatriptan. We evaluated the impact of these covariates on the plasma concentration (Cp) profile of sumatriptan administered subcutaneously.Methods
We conducted three pharmacokinetic studies of subcutaneous sumatriptan in 98 healthy adults. Sumatriptan was administered subcutaneously (236 administrations) as either DFN-11 3 mg, a novel 0.5 mL autoinjector being developed by Dr. Reddy's Laboratories; Imitrex(®) (Sumatriptan) injection 3 mg or 6 mg (6 mg/0.5 mL); or Imitrex STATdose 4 mg or 6 mg (0.5 mL). Blood was sampled for 12 hours to determine sumatriptan Cp. Maximum Cp (Cmax), area under the curve during the first 2 hours (AUC0-2), and total area under the curve (AUC0-∞) were determined using noncompartmental methods. Post hoc analyses were conducted to determine the relationship between these exposure metrics and each of body weight, BMI, age, sex, and race (categorized as white, black, or others).Results
Both weight and BMI correlated negatively with each exposure metric for each treatment group. Across all treatment groups, AUC0-2 for subjects with BMI less than or equal to median value was 1.03-1.12 times the value for subjects with BMI more than median value. For subjects with BMI less than or equal to median value receiving DFN-11, median AUC0-2 was slightly less than that for subjects with BMI more than median value receiving Imitrex 4 mg and larger than that for subjects with BMI more than median value receiving Imitrex 3 mg. Results were similar for the other exposure metrics and for weight. Exposure was higher in women than in men, which can be attributed in part to differences in weight. There was no relationship between exposure and age. For DFN-11, AUC0-2 and AUC0-∞ were lower in nonwhites compared with whites; the ratio of median values was 0.84 and 0.89, respectively. A similar, nonstatistically significant, trend was observed in the other products (ratio of median values ranging from 0.84 to 0.89).Conclusion
Weight and BMI appear to be important covariates for sumatriptan exposure: subjects with lower values for either metric of body size have higher systemic exposure compared with subjects with higher values. Additional studies are required to determine if doses of subcutaneous sumatriptan may be adjusted based on BMI for comparable efficacy and a potentially improved tolerability profile.Many UC-authored scholarly publications are freely available on this site because of the UC's open access policies. Let us know how this access is important for you.
Main Content
For improved accessibility of PDF content, download the file to your device.
Enter the password to open this PDF file:
File name:
-
File size:
-
Title:
-
Author:
-
Subject:
-
Keywords:
-
Creation Date:
-
Modification Date:
-
Creator:
-
PDF Producer:
-
PDF Version:
-
Page Count:
-
Page Size:
-
Fast Web View:
-
Preparing document for printing…
0%